Xycd60 Manual [best] 90%

Connect to your Battery (if in charge mode) or Load (if in discharge mode).

When OP is set to any value greater than 00:00 , the module will turn the relay off automatically when the timer expires, regardless of whether the voltage limit (UP) has been reached. This is useful as a safety backup to prevent unlimited charging if the battery has a fault and cannot reach UP.

This operational guide details the specific technical specifications, wiring configurations, programming variables, and step-by-step procedures to customize your XY-CD60 module on ICStation or similar online platforms. Technical Specifications Summary xycd60 manual

High-definition LCD screen showing voltage, percentage, and time. Modes: Charging Mode ( UP ) and Discharging Mode ( dn ). Operating Modes Explained 1. Charging Mode (UP)

If you're looking for additional resources or support, here are some options: Connect to your Battery (if in charge mode)

A unique feature mentioned in eBay listings allows for a "forced start" to account for instantaneous voltage drops when a heavy load first turns on, preventing the controller from immediately tripping into protection mode.

| Parameter | Charging Mode (P‑1 / IN) | Discharging Mode (P‑2 / OUT) | | :-------- | :---------------------------- | :------------------------------- | | | To turn a battery charger on/off based on battery voltage. | To turn a load on/off based on battery voltage. | | Wiring | Charger connected to IN terminals; battery connected to OUT terminals. | Battery connected to IN terminals; load connected to OUT terminals. | | Action Logic | Relay ON when battery voltage ≤ dn (charger starts). Relay OFF when battery voltage ≥ UP (charger stops). | Relay ON when battery voltage ≥ UP (load powered). Relay OFF when battery voltage ≤ dn (load disconnected). | | Display Icon | IN flashes when relay is ON (charging). | OUT flashes when relay is ON (discharging). | | Time Functions Available | OP (max charging time) dOP (delay before restarting) | OP (max discharging time) dOP (delay before restarting) FOP (forced‑on time, 0–10 s) | Operating Modes Explained 1

If you have a handheld, high-lumen flashlight likely powered by an 18650 battery, you have this version. The official manufacturer's documentation is rarely included, but all the information you need is here in a structured format.

The is a highly versatile, dual-mode battery charge and discharge controller module designed to protect DC 6V to 60V lead-acid and lithium batteries from overcharging and over-discharging . It functions strictly as a voltage-controlled switch via an onboard mechanical relay, meaning it does not modify or regulate output voltage or current on its own. Instead, it safely intercepts and handles your external charging source or electrical load based on user-configured voltage thresholds.

30A (Requires thick wiring for high currents). Voltage Precision: 0.1V. Display: HD LCD Screen with Real-time Voltage and Status.